10 years

Sicurgraf

Lifeline for standing seam sheet metal roofing

  • Specific product for installation on double-seam sheet metal
  • Certified and compliant system
    • UNI EN 795:2012 for one person
    • UNI CEN/TS 16415:2013 for two (code 002797) or four people (code 002798/002809/002810 + 002832)
    • UNI 11578:2015 for two (code 002797) or four people (code 002798/002809/002810 + 002832)
  • Recommended use by one person as a pendulum effect
  • In pickled AISI 304 stainless steel
  • 10-year warranty

 

Product
002798
Template
SS SGF4-50 anchor Standing Seam Met
Details
Stainless steel extremity anchorage Type A or C (4 persons) for Standing Seam Metal sheet with 380-455mm distance between centres.
Product
002809
Template
SS SGF4-60 anchor Standing Seam Met
Details
Stainless steel extremity anchorage Type A or C (4 persons) for Standing Seam Metal sheet with 480-555mm distance between centres.
Product
002810
Template
SS SGF4-67 anchor Standing Seam Met
Details
Stainless steel extremity anchorage Type A or C (4 persons) for Standing Seam Metal sheet with 550-625mm distance between centres.
Product
002802
Template
SS SGF2C anchor Standing Seam Metal
Details
Stainless steel Type C anchorage for Standing Seam Metal sheet
Product
006650
Template
49-Wire cable dn8 SS 316
Details
Cable In AISI 316 stainless steel Ø 8 mm 49 strands with identification bar for product traceability.
Product
000033
Template
SS 304 Lifeline Energy Absorber
Details
AISI 304 stainless steel energy absorber. Essential for lifelines shorter than 40–50 m in order to reduce loads on the supports.
Product
001758
Template
Quick release carabiner
Details
Quick release carabiner (not usable with SICURSLIM)
Product
001513
Template
Kit dn8 cable clamping
Details
AISI 304 stainless steel kit for clamping 8 mm diameter cable, composed of: 4 AISI 304 stainless steel clamps, 1 stainless steel thimble d. 8 mm and 2 heat-shrinkable sleeves.
Product
000032
Template
Double articulated jaw turnbuckle
Details
Closed-body turnbuckle in AISI 316 stainless steel for tensioning steel cable, with two articulated jaw ends.
Product
002494
Template
Fork / swage turnbuckle
Details
AISI 304 stainless steel turnbuckle with 150 mm closed swage terminal. One end fixed fork with Ø12×50 mm locking bolt, other end swage terminal. Hardware included: M12 A2-70 bolt, nut and 2 washers.
Product
002493
Template
AISI 304 SS F/F tensioner
Details
Closed-body turnbuckle in AISI 304 stainless steel for cable tensioning, with two fixed jaw ends.
Product
002477
Template
Tensioner with swage to crimp+bol
Details
Tensioner with 250 mm thread in AISI 316 stainless steel for crimping on lifeline. Includes fasteners: 2 nuts and 1 washer.
Product
000294
Template
Art fork/swage terminal turnbuckle
Details
Closed-body turnbuckle for tensioning stainless steel AISI 316 cable with one articulated fork end and one swage terminal end.
Product
000293
Template
Jaw terminal/Swage to crimp
Details
Terminal with jointed jaw, with crimping sleeve in stainless steel AISI 316
Product
000292
Template
Jaw terminal/Swage to crimp
Details
Terminal with fixed jaw, with crimping sleeve in stainless steel AISI 304
Product
000789
Template
Male eyebolt M16 + bolt
Details
Male eyebolt M16 + bolt
Product
001344
Template
Vertical fairlead adj0-45 for Shut
Details
Adjustable vertical fairlead 0–45° for shuttle with hardware: 1 hex head bolt M16x35, 1 countersunk head bolt M16x35 + self-locking nut and Ø16 washer, stainless steel AISI 304.
Product
000501
Template
Intermediate Cable Guide AISI 304
Details
Intermediate cable guide in AISI 304 stainless steel with fasteners: M16 self-locking nut and Ø16 mm washer.
Product
000192
Template
Vrt. fairlead for trolley W/bolt
Details
Vertical fairlead for trolley with bolts included: 1 hex head bolt M16x35, 1 countersunk head bolt M16x35, plus self-locking nut and Ø16 washer, stainless steel AISI 304.
Product
000291
Template
Lifeline identification code
Details
Lifeline identification code
Product
000290
Template
Seal for tensioner block
Details
Seal for tensioner block
Product
000194
Template
Turnbuckle / Tube Support
Details
AISI 304 stainless steel support for installing a turnbuckle with closed body or tube. Includes fasteners: M16×35 mm bolt and Ø16 mm stainless steel washer.

Lifeline FAQs.

It is a linear anchoring system, that is, a line (flexible or rigid) between end and/or intermediate anchors, to which the operator is attached. The operator is required to wear Category III PPE (Personal Protective Equipment) to protect against falls, secured to the line either by a connector or a mobile anchor point.

The durability of a product is defined by the manufacturer, but depends on many factors including the quality of the materials used, their use, atmospheric agents, environmental conditions of the place where the lifeline is installed, etc.

Yes, a lifeline must be certified according to the reference technical standards: UNI EN 795:2012 (for removable devices types A and C), CEN/TS 16415:2013 (for removable devices types A and C) and UNI 11578:2015 (for permanent devices types A and C).

Whether a lifeline complies with one or more of the above standards depends on its intended use, and therefore it does not necessarily have to comply with all three standards at the same time.

It is the manufacturer's responsibility to issue a declaration attesting the product's compliance with the reference standard.

No. All lifelines composed of anchors compliant with the UNI 11578:2015 standards (for permanent type A and C devices), UNI EN 795:2012 (for removable type A and C devices) and CEN/TS 16415:2013 (for removable type A and C devices) are suitable for use with PPE against falls from a height.

The only certified connections between lifelines or type B webbing and PPE (Personal Protective Equipment) are connectors compliant with UNI EN 362.

The choice depends on the characteristics of the supporting structure. In the event of a fall, rigid poles generate significant forces, which are then transmitted to the anchors and the supporting structure; deformable poles, on the other hand, absorb more loads, transferring less to the anchors and supporting structure. Therefore, where the supporting structure is not suitable for withstanding high stresses, elastoplastic deformation poles are preferable.

The UNI EN 795:2012 standard does not specify any particular material, but recommends that the cable does not show any corrosion and that, in the case of galvanized wire ropes, the galvanization complies with ISO 2232.

The number depends on the standard according to which the lifeline is certified and must be indicated by the manufacturer in the user manual.

There are many possible fastening methods, each closely related to the type of structure on which the anchoring system is installed. They can be secured using a plate and counterplate, screws and nuts, or using rods and two-component resins, wood screws, mechanical anchors, rivets, clamps, etc. However, it remains the responsibility of the engineer in charge to verify the type of anchor and the structure and indicate its characteristics and dimensions.

Anchor points allow movement only in a circular area with a radius equal to the length of the lanyard, while lifelines allow linear movement along their entire length.

The choice of which fall protection system to adopt is the employer's responsibility, who selects the most suitable system based on the protective function it must fulfill (for example, installing a guardrail to protect against the risk of falling through the floor would be pointless). However, as indicated by Legislative Decree 81/2008, collective protection systems are preferable in the event of a risk of falling from an edge.

Connection to a lifeline by a rope access worker can be considered safe if the manufacturer has provided for this and reported it in the user manual issued by the manufacturer and if the operating conditions allow it.

Roof renovation is an extraordinary maintenance project, meaning it doesn't fall under the scope of work that can be performed using a lifeline. It is, in fact, suitable for performing ordinary maintenance work, such as radio and television antenna repairs, Faraday cage maintenance, maintenance of roofing systems, re-roofing/replacing waterproofing membranes and sheaths, gutters cleaning, satellite dish repairs, solar panel or photovoltaic system installation or maintenance, etc.

Yes, subject to a risk assessment by a qualified technician and in compliance with current regulations regarding safety against falls from heights.

UNI 11560:2022 indicates that the documentation to be provided to the client must contain:

  • Anchoring system configuration design (Technical Information for System Use), carried out by the anchoring system designer on the basis of the risk assessment.
  • Structural designer's verification project relating to the type of anchor to the supporting structure based on the type of material of the structure (Calculation Report).

According to Appendix A2 of UNI EN 795:2012 – Guide for documentation to be provided after installation, the necessary documentation that must be provided to the customer must include:

  • Schematic installation plan showing the address and location of the installation, the name and address of the installation company, the name of the person responsible for the installation, product identification (name of the anchor device manufacturer, type, model/article), fixing device (manufacturer, product, permissible tensile and transverse forces), schematic installation plan and relevant information for the user/client, such as the arrangement of the anchor points.

This plan should be posted at the entry point to the building so that it is visible or available to everyone.

  • Declaration of correct installation provided by the responsible installer, which must contain the following information regarding the anchor device: declaration of conformity of the installation with the installation instructions provided by the manufacturer in the use and maintenance manual, declaration of execution according to the installation plan, referred to above, declaration of fixing to the specified substrate and in the specified manner (number of bolts, correct materials, correct position, correct location), declaration that the work was commissioned in accordance with the manufacturer's information, photographic information/documentation.
  • Declaration of conformity of materials and instruction manuals for assembly, use and maintenance, issued by the manufacturer of the anchoring system.

To answer the question, it is necessary to distinguish between load-bearing and non-load-bearing structures.

If the roof is practicable, it falls within the scope of fall protection systems and it is therefore necessary to proceed with a risk assessment to choose the most suitable protection system.

However, if the roof is not accessible or load-bearing, the installation of permanent devices is not possible, as access and transit are not foreseen.

Ask for more information

* Obligate fields
*
Newsletter
Sign up and stay updated on courses and new products for your safety.
* Obligate fields
*
*
Telephone +39 059 81 81 79
Registered and operational headquarters Via dei Mestieri 12 - 41030 Bastiglia (MO) Italy
SOCIAL
Scroll